See how electrical outlets for the home are wired. Get a Quick Reply! Ask the Electrician. Electrical Video 1 Electrical Wiring Tips? How to install a sub-panel in a amp service for a volt 30 amp dryer…. Electrical Video 1 Electrical Wiring Tips. Helping You to Wire It Right! See the Electrical Wiring Video 2 Below:. Identifying and Measuring Electrical Current. Installing a Switch for a Volt Pump. The Non-Contact Electrical Tester. Simply insert the end of the tester into an outlet, lamp socket, or hold the end of the tester against the wire you wish to test.

Very handy and easy to use. The Plug-In Outlet Tester. So basically, everything starts with planning the load that will be placed on the sub panel, and then we calculate the wire size feeding the sub panel based upon the distance. It is also important to factor in any electric motors that may be used due to the starting load which will effect the amperage and the voltage. Michael asks: We bought a house with a detached shop.

With every breaker shut off, the lights and outlets still work. They still have power. Only when I shut the amp breaker off does the lights and outlets quit working. I can understand a possible bad breaker, but all defective. I highly doubt that. What do you think? From what you have described, I think there is another panel somewhere.

One way to know for sure is to open the panel and see if there is a spare set of lugs that are used to feed another panel. Get a Quick Reply! Ask the Electrician. Careful planning for your Sub-Panel with immediate and future load considerations will help you understand how to size your Sub-Panel. This information will help as you consider a Sub-Panel and its size. Cinda from Souderton, Pennsylvania. More about Wiring a Sub Panel Grounds and Neutrals in Electrical Panel How to Wire Grounds and Neutrals in Sub Panels — all the neutrals and ground wire and terminal bars must be separated from each other, and your sub feed should be a 4-wire cable that has a separated insulated neutral wire and a separate ground wire.

Sub Panel Grounding and Neutrals Understanding Grounding for Sub Panels: When you add a second electrical panel with separate neutral and common bars, do you ground the common to the box along with a ground rod connection? Sub Panels are installed and used for several reasons including expanding the circuit breaker capacity of the main electrical panel.

Learn more about wiring a sub panel. See How to Wire it Right! Complete Guide to Home Electrical Wiring. Ricardo Mitchell.

Support wikiHow by unlocking this expert answer. Not Helpful 0 Helpful 1. Not Helpful 0 Helpful 0. Not Helpful 2 Helpful 2. A residential panel should always consist of two V connections of opposite phase the "hots" plus a neutral connection.

If you put a breaker in either the main panel or subpanel, you'll get a branch circuit using just one of the hots plus the neutral, so you get V. Not Helpful 6 Helpful What is the largest sub-panel that can be used for a amp main breaker box? A sub-panel box -- if wired with the proper gauge wire and protected with the correct breakers -- can be any size that covers the amps that its rated for and protected against.

Not Helpful 9 Helpful If I run 2 10 wires to a subpanel using 2- 30 amp breakers, is this a 30 amp or a 60 amp subpanel? It will be a 30 amp volt, if you catch each hot leg, but code requires using one double-pole 30 amp breaker to do that, and you still need to connect the neutral and ground between the panels four wires in total: 2-hot, 1-neutral, 1-ground.

Not Helpful 5 Helpful Call an electrician. It could be a miswired hot wire, or a back feeding neutral. Or someone could have used white insulation wire for running a hot wire and not identified it and then added to the neutral bar. Use a meter and be careful. Do I need the 4th wire if the sub panel is installed alongside the main panel? The ground and neutral wires are only connected in one place, the main breaker panel.

Not Helpful 7 Helpful Include your email address to get a message when this question is answered. Be sure all power has been shut off from the main panel before you begin working to prevent accidentally shocking yourself. By using this service, some information may be shared with YouTube. You Might Also Like How to. How to. More References 9. About This Article. Co-authored by:. Co-authors: Updated: November 21, Categories: Electrical Wiring and Safety Switches.

Thanks to all authors for creating a page that has been read , times. What I realize I'm going to have to do is only use half of my sub panel because I only have 3 wires coming from the main panel and I need 2 hot wires to utilize the entire sub panel. More reader stories Hide reader stories. Did this article help you? Cookies make wikiHow better. By continuing to use our site, you agree to our cookie policy. Merrie Davis Jun 6, Anonymous Feb 11, Anonymous Feb 22, Anonymous Oct 20, Anonymous Jan 30, Share yours!